Wellhead Inspection Checklist

API 6A aligned inspection record: wellhead and Christmas tree equipment

Company logo

PAGE 1 OF 2

Well & Inspector Details
Current Pressure Readings

Inspection Items

Mark the applicable column for each item: P = Pass  |  F = Fail  |  N/A = Not applicable. Record notes for any F.

# Check P F N/A Notes / Action
Casing Head & Tubing Head
1Casing head: no external corrosion, erosion or mechanical damage
2Tubing head: no external corrosion, erosion or mechanical damage
3Casing hanger lockdown screws torqued and secure
4Casing annulus pressure within expected range, no sustained abnormal pressure
Flanges, Ring Gaskets & Bolting
5Flange faces clean and undamaged at each connection
6Ring gasket type and material correct per API 6A specification
7No visible leaks at any flanged joint (hydrocarbon staining, drips, gas)
8Stud bolts and nuts: all present, correct length, proper nut engagement
9Stud bolts: no excessive corrosion, pitting or cross-threading
Christmas Tree Valves
10Master valve: operates fully open to fully closed, no external leaks
11Wing valve(s): operate smoothly, position indicators correct
12Swab valve: operates fully, bonnet bolts secure
13Kill valve: operates fully, accessible and not obstructed
14Valve handwheels / actuators: undamaged, stems not bent
15Valve position indicators aligned with actual valve position
Wellhead Inspection - Page 2 of 2
Well
Date
Inspector
# Check P F N/A Notes / Action
Pressure Gauges & Choke
16Tubing, casing and annulus pressure gauges readable and functional
17Gauge calibration within date (check calibration sticker)
18Gauge isolation valves operate correctly
19Choke bean or adjustable choke: no erosion at choke body, correct setting
Corrosion & Cathodic Protection
20External corrosion assessment: none / surface / pitting / severe
21Cathodic protection system status: anodes present / impressed current active
22CP test point cables intact, pipe-to-soil reading recorded (if accessible)
23Protective coating condition (painted surfaces, wraps): acceptable
Wellhead Cellar & BOP Points
24Wellhead cellar clean and drained, no standing fluids
25No hydrocarbon accumulation or gas odour in cellar
26BOP flange condition (if applicable): stud holes aligned, ring groove undamaged
27Flange protectors in place when BOP not installed
Safety Systems
28Surface safety valve (SSV): function test performed, closes on command
29Emergency shutdown (ESD) valve: responds within required time
30Fire loop / fusible plug: condition acceptable, not damaged or corroded
31SCADA communication confirmed: wellhead data transmitting to control room
32Wellhead identification plate legible and correct
Overall Result
PASS: all items satisfactory, wellhead integrity confirmed FAIL: defect(s) identified, see table below

Defects & Action Required (list any item marked F: reference item # from checklist)

Item # Defect description Action taken / reported to Rectified by / date

Declaration

I declare that I have completed this wellhead inspection in accordance with API 6A requirements and the site integrity management plan. I have recorded all findings accurately and reported any defects or anomalies to the well operations supervisor and the integrity management team. Any critical defects affecting pressure containment or well control barriers have been escalated immediately. I understand that failure to complete inspections or report defects may breach regulatory obligations and the facility safety case.

Inspector Sign-off
Signature
Print name
Date & time
Well Operations Supervisor Acknowledgement
Signature
Print name
Date