Hydrogen sulfide safety equipment inspection per API RP 55.
PAGE 1 OF 2
Inspection Items
Mark the applicable column for each item: P = Pass | F = Fail | N/A = Not applicable. Record notes for any F.
| # | Check | P | F | N/A | Notes / Action |
|---|---|---|---|---|---|
| Personal H2S Monitors | |||||
| 1 | Monitor calibrated within manufacturer-specified interval | ||||
| 2 | Daily bump test performed and documented before use | ||||
| 3 | Low alarm setpoint confirmed at 10 ppm | ||||
| 4 | High alarm setpoint confirmed at 15 ppm (or site-specific threshold) | ||||
| 5 | Sensor within manufacturer replacement life, no drift observed | ||||
| Fixed Gas Detectors | |||||
| 6 | Fixed detectors operational and displaying readings | ||||
| 7 | Calibration current per manufacturer schedule (certificate on file) | ||||
| 8 | Detector placement per API RP 55 (downwind, breathing zone height) | ||||
| 9 | Alarm relays and control panel communication verified | ||||
| Wind Socks / Direction Indicators | |||||
| 10 | Wind socks installed at all required locations and visible | ||||
| 11 | Wind socks in good condition, not torn or faded beyond recognition | ||||
| 12 | Wind direction indicators operational (if electronic type installed) | ||||
| SCBA Equipment | |||||
| 13 | SCBA units staged at designated safe briefing areas (SBAs) | ||||
| 14 | Air cylinders fully charged (min. 2,216 psi / 4,500 psi per type) | ||||
| 15 | Face seals, straps, and regulators in good working order | ||||
| 16 | SCBA hydrostatic test current (cylinder within test date) | ||||
| # | Check | P | F | N/A | Notes / Action |
|---|---|---|---|---|---|
| Breathing Air Stations | |||||
| 17 | Cascade system or breathing air compressor operational | ||||
| 18 | Air quality tested and meets Grade D breathing air standard | ||||
| 19 | Supply hoses and fittings inspected, no leaks or damage | ||||
| Warning Systems | |||||
| 20 | Audible alarm systems tested and functional (horns, sirens) | ||||
| 21 | Visual alarm indicators operational (strobes, beacon lights) | ||||
| 22 | H2S warning signs posted at all entry points and hazard areas | ||||
| Emergency Shutdown | |||||
| 23 | Emergency shutdown stations identified, accessible and labeled | ||||
| 24 | ESD valves functional and fail-safe position verified | ||||
Deficiencies & Corrective Actions (list any item marked F: reference item # from checklist)
| Item # | Deficiency description | Corrective action / reported to | Corrected by / date |
|---|---|---|---|
Declaration
I declare that I have completed this H2S safety equipment inspection in accordance with API Recommended Practice 55 and applicable site-specific H2S contingency plan requirements. All deficiencies have been reported to the responsible party. Equipment found non-functional must be replaced or repaired before personnel enter the H2S-classified area.