Monthly inspection record for baghouse, cartridge and cyclone dust collection systems
PAGE 1 OF 2
Inspection Items
Mark the applicable column for each item: P = Pass | F = Fail | N/A = Not applicable. Record notes for any F.
| # | Check | P | F | N/A | Notes / Action |
|---|---|---|---|---|---|
| Filters | |||||
| 1 | Filter bags or cartridges: no visible tears, holes or damage (visual from access door) | ||||
| 2 | Filter media: no moisture staining, chemical discolouration or blinding | ||||
| 3 | Filter cages (baghouse): not bent, corroded or dislodged from tube sheet | ||||
| 4 | Tube sheet or mounting plate: seals intact, no dust bypass around filter seats | ||||
| Pulse-Jet Cleaning System | |||||
| 5 | Pulse valves: all firing consistently during manual cleaning cycle | ||||
| 6 | Compressed air pressure at manifold: within specification (typically 400-600 kPa) | ||||
| 7 | Compressed air quality: no oil or moisture at drain point | ||||
| 8 | Timer or controller: settings correct, sequence cycling as programmed | ||||
| 9 | Air manifold and piping: no leaks, connections secure | ||||
| Housing & Hopper | |||||
| 10 | Collector housing: no corrosion, dents, weld cracks or structural damage | ||||
| 11 | Access doors: seals and gaskets intact, doors close securely | ||||
| 12 | Hopper: no material bridging or blockage, walls clear | ||||
| 13 | Discharge mechanism (airlock / screw / dump valve): rotating freely, seals intact | ||||
| 14 | Airlock drive: chain or belt tension correct, motor running smoothly | ||||
| Ductwork & Hoods | |||||
| 15 | Capture hoods: correctly positioned, no damage, adequate capture velocity | ||||
| 16 | Duct joints and flexible connections: no leaks, tears or disconnections | ||||
| 17 | Dampers: set to correct positions, operating freely | ||||
| 18 | Duct condition: no dents, holes, excessive wear or dust accumulation inside | ||||
| # | Check | P | F | N/A | Notes / Action |
|---|---|---|---|---|---|
| Fan & Motor | |||||
| 19 | Fan vibration: reading within acceptable limits, no abnormal noise | ||||
| 20 | Fan bearings: temperature acceptable, no excessive heat or noise | ||||
| 21 | Fan wheel: no build-up, erosion, cracks or imbalance | ||||
| 22 | Drive belts (if belt-driven): correct tension, no fraying, cracking or glazing | ||||
| 23 | Motor current draw: within nameplate rating, no overload | ||||
| 24 | Fan inlet and outlet: no obstructions, inspection doors secure | ||||
| Explosion Protection | |||||
| 25 | Explosion vent panels: intact, unobstructed, rupture indicator not tripped | ||||
| 26 | Isolation valves (flap or chemical): in service, within test date | ||||
| 27 | Suppression system (if fitted): armed, canisters within service date | ||||
| 28 | Grounding and bonding: earth connections intact on collector, ductwork and hoods | ||||
| 29 | Spark arrestor (if fitted): condition acceptable, no blockage | ||||
| Monitoring Instruments | |||||
| 30 | Magnehelic or digital DP gauge: calibrated, reading correctly | ||||
| 31 | Broken bag detector (triboelectric or opacity): functional, alarm set-point verified | ||||
| 32 | Stack emissions monitor (if required): operational, within calibration date | ||||
| Housekeeping & General | |||||
| 33 | No accumulated dust on collector exterior, surrounding floors, beams or ledges | ||||
| 34 | Dust disposal: collection bin or bag not overfull, disposed of correctly | ||||
| 35 | Warning signs and labels: legible, in place (hazard, explosion risk, PPE) | ||||
Defects & Action Required (list any item marked F: reference item # from checklist)
| Item # | Defect description | Action taken / reported to | Rectified by / date |
|---|---|---|---|
Declaration
I declare that I have completed this dust collector inspection in accordance with site procedures and relevant Australian Standards. I have recorded all findings accurately and reported any defects or non-compliant items to my supervisor. The dust collection system will not be returned to service until any faults that affect worker health, safety or environmental compliance have been rectified. I understand that failure to complete scheduled inspections or report defects may breach company policy and WHS obligations.