API 53 aligned: visual inspection, function test and pressure test record
PAGE 1 OF 2
Visual Inspection & Function Tests
Mark the applicable column for each item: P = Pass | F = Fail | N/A = Not applicable. Record notes for any F.
| # | Check | P | F | N/A | Notes / Action |
|---|---|---|---|---|---|
| Ram BOP - Visual Inspection | |||||
| 1 | Ram bodies: no corrosion, erosion, cracks or mechanical damage | ||||
| 2 | Bonnets and bonnet bolts: secure, torqued to specification, no visible damage | ||||
| 3 | Ring gaskets: seated correctly, no extrusion, cracking or damage | ||||
| 4 | Ram type matches drill string: pipe ram size correct for current drill pipe OD | ||||
| 5 | Blind / shear rams: rated to cut heaviest tubular in the hole | ||||
| 6 | Ram packers: condition acceptable, no excessive wear or damage | ||||
| Annular Preventer | |||||
| 7 | Packing element: condition acceptable, wear within limits | ||||
| 8 | Closing pressure: within manufacturer specification | ||||
| 9 | Opening pressure: within manufacturer specification | ||||
| 10 | Body and housing: no cracks, corrosion or hydraulic leaks | ||||
| Hydraulic Control System | |||||
| 11 | Hydraulic fluid level: correct in reservoir | ||||
| 12 | Control pods: functioning, no leaks or damage | ||||
| 13 | Pilot valves and shuttle valves: operating correctly | ||||
| 14 | Hydraulic hoses and fittings: no chafing, bulging, leaks or damage | ||||
| 15 | Primary control station: all functions operational | ||||
| 16 | Secondary (remote) control station: all functions operational | ||||
| Function Test Results (record times in seconds) | |||||
| 17 | Ram BOP 1 close time (API 53 max: 30 sec) | ||||
| 18 | Ram BOP 2 close time (API 53 max: 30 sec) | ||||
| 19 | Annular preventer close time (per manufacturer spec) | ||||
| 20 | Choke and kill valves: full stroke confirmed | ||||
| 21 | Hydraulic connector: lock and unlock functions confirmed | ||||
| # | Check | P | F | N/A | Notes / Action |
|---|---|---|---|---|---|
| Accumulator System | |||||
| 22 | Pre-charge pressure: each bottle within specification | ||||
| 23 | Total usable volume: sufficient to close all BOPs plus reserve per API 53 | ||||
| 24 | Pump output rate: meets minimum specification | ||||
| 25 | Auto pump cut-in / cut-out: triggers at correct pressures | ||||
| 26 | Accumulator bottles: no visible damage, corrosion or leaks | ||||
| Choke & Kill Manifold | |||||
| 27 | Manifold valves: operate freely, no leaks | ||||
| 28 | Choke: adjustable choke functions correctly, no wash-out | ||||
| 29 | Pressure gauges: accurate, readable, not damaged | ||||
| 30 | Line connections: secure, no leaks or damage at all fittings | ||||
| Pressure Testing (record psi & hold time) | |||||
| 31 | Ram BOP 1 - low-pressure test (200-300 psi, 5 min hold) | ||||
| 32 | Ram BOP 1 - high-pressure test (rated WP, 5-10 min hold) | ||||
| 33 | Ram BOP 2 - low-pressure test (200-300 psi, 5 min hold) | ||||
| 34 | Ram BOP 2 - high-pressure test (rated WP, 5-10 min hold) | ||||
| 35 | Annular - low-pressure test (200-300 psi, 5 min hold) | ||||
| 36 | Annular - high-pressure test (rated WP, 5-10 min hold) | ||||
| Emergency & Backup Systems | |||||
| 37 | Deadman system: activates BOP closing on comms loss | ||||
| 38 | Autoshear system (subsea): functions correctly | ||||
| 39 | Acoustic backup control: communicates with BOP stack | ||||
| 40 | Emergency disconnect sequence: verified (subsea) | ||||
Defects & Corrective Actions (list any item marked F: reference item # from checklist)
| Item # | Defect description | Action taken / reported to | Rectified by / date |
|---|---|---|---|
Declaration
I declare that I have completed this BOP inspection and testing in accordance with API Standard 53 and applicable regulatory requirements. I have recorded all findings accurately and reported any defects or non-compliant items to the toolpusher / OIM. The BOP will not be returned to service until any faults affecting well control capability have been rectified and re-tested. I understand that failure to complete an inspection or report defects may breach company well control policy and regulatory obligations.